Nominal voltage | |
---|---|
Specific value | 24 VDC |
Limit values, min/max | 11/30 VDC |
Nominal current, typically | |
Specific value | 150 mA |
Condition | unloaded |
Insulation strength | <= 2 kV |
Signal form | Square |
Incremental signals, square | |
Channels | K1+, K1-, K2+, K2- |
Phase position, electrically | 90 ° |
Zero pulse, square | |
Channel (Channels) | K0+, K0- |
Number of revolutions | 1x |
Impulses, square wave | 1024 |
2048 | |
4096 | |
8192 | |
16384 | |
32768 | |
Output driver, HTL | |
Output level | Push-Pull, supply voltage |
Load current | <= 30 mA |
Output frequency | <= 150 kHz, ± 15 ° |
Parameter/Function, changeable | Number of pulses |
Type of parametrization | Factory setting |
Maximum Speed, mechanically | <= 3000 1/min |
Shaft load, axial/radial | Own mass |
Bearing life time | >= 10.7E+9 revolutions |
Bearing life time - Parameter | |
Speed | 3000 1/min |
Operating temperature | 60 °C |
Angular acceleration | <= 10E+4 rad/s² |
Moment of inertia, typically | 28.6E-6 kg m², at Ø16 mm |
Start-up torque, 20 °C | 5 Ncm |
Concentricity tolerance | ± 0.05 mm |
Mass, typically | 1.7 kg |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |